Every glove on this page is a Class 3 rubber insulating glove, based on the manufacturer's specifications or product labeling. Class 3 gloves have a maximum use voltage of 26,500 volts AC under OSHA 29 CFR 1910.137, Table I-4, and carry a green ASTM D120 label.
Class 3 sits between Class 2 (17,000 V) and Class 4 (36,000 V) for high-voltage utility and line work. Your electrical safety program and qualified person should confirm the exposure voltage before choosing a class.
Choose from Novax® (PIP®) gloves in 14", 16" and 18" lengths, with straight, bell and contour cuffs. Longer gloves add forearm coverage.
Wear leather protectors over rubber insulating gloves to guard against cuts, punctures and abrasion. Protectors add no electrical insulation of their own, and OSHA requires a retest after any use without them. Under OSHA 29 CFR 1910.137, rubber insulating gloves must be inspected and air-tested before each day's use and electrically tested before first issue and every 6 months after that. Our dielectric glove testing service covers the retest cycle.